Product Description
Part Number: 3051CD3A02A1BS5I1M5C1Q4
Ordering Information
Model: 3051C1 - Coplanar Pressure Transmitter
Measurement type: D - Differential
Pressure range: 3 - -1000 to 1000 inH20 (-621,60 to 621,60 mbar)
Transmitter output: A2 - 4-20 mA with Digital Signal Based on HART Protocol
Materials of construction: 0 - Alternate Process Connection
Isolating diaphragm: 23 - 316L SST
O-Ring: A - Glass-filled PTFE
Sensor: 1 - Silicone
B - [Housing material] Aluminium; [Conduit entry size] M20 x 1.5
Manifold assembly4: S5 - Assemble to Rosemount 305 Integral Manifold
Product certifications: I15 - ATEX Intrinsic Safety and Dust
Display and interface options: M5 - LCD Display
Software configuration: C16 - Custom Software Configuration (completed CDS 00806-0100-4007 for wired and 00806-0100-4100 for Wireless required with order)
Calibration certificate: Q4 - Calibration Certificate
Select Configuration Buttons (option code D4 or DZ) or Local Operator Interface (option code M4) if local configuration buttons are required.
Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output.
Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
Assemble-to items are specified separately and require a completed model number.
Dust approval not applicable to Output Code X.
Only available with HART 4-20 mA Output (output code A) and Wireless Output (output code X)
Note: This item complete with manifold 0305RC52B11(C305131124).
Estimated Lead Time: 5 days
Shipping Weight: 10 Kg
Ordering Information
Model: 3051C1 - Coplanar Pressure Transmitter
Measurement type: D - Differential
Pressure range: 3 - -1000 to 1000 inH20 (-621,60 to 621,60 mbar)
Transmitter output: A2 - 4-20 mA with Digital Signal Based on HART Protocol
Materials of construction: 0 - Alternate Process Connection
Isolating diaphragm: 23 - 316L SST
O-Ring: A - Glass-filled PTFE
Sensor: 1 - Silicone
B - [Housing material] Aluminium; [Conduit entry size] M20 x 1.5
Manifold assembly4: S5 - Assemble to Rosemount 305 Integral Manifold
Product certifications: I15 - ATEX Intrinsic Safety and Dust
Display and interface options: M5 - LCD Display
Software configuration: C16 - Custom Software Configuration (completed CDS 00806-0100-4007 for wired and 00806-0100-4100 for Wireless required with order)
Calibration certificate: Q4 - Calibration Certificate
Select Configuration Buttons (option code D4 or DZ) or Local Operator Interface (option code M4) if local configuration buttons are required.
Option HR5 configures the HART output to HART Revision 5. Option HR7 configures the HART output to HART Revision 7. The device can be field configured to HART Revision 5 or 7 if desired. HART Revision 5 is the default HART output.
Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
Assemble-to items are specified separately and require a completed model number.
Dust approval not applicable to Output Code X.
Only available with HART 4-20 mA Output (output code A) and Wireless Output (output code X)
Note: This item complete with manifold 0305RC52B11(C305131124).
Estimated Lead Time: 5 days
Shipping Weight: 10 Kg