Product Description
Part Number: 3144PD2A1NAB5M5Q4
Model: 3144P Temperature Transmitter
Manufacturer: Rosemount-Emerson
Condition: New Original in Factory Packing
Factory Warranty: Two Years
Specifications
Input: Dual and single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)
Output Signal: 4-20 mA /HART® protocol, FOUNDATION™ Fieldbus protocol
Housing: Dual-compartment field mount
Display/Interface: Large LCD display with percent range graph and buttons/switches
Diagnostics: Basic diagnostics, Hot Backup™ capability, sensor drift alert, thermocouple degradation, min/max tracking
Calibration Options: Transmitter-sensor matching (Callendar-Van Dusen constants), custom trim
Certifications/Approvals: SIL 2/3 certified to IEC 61508 by an independent 3rd party, hazardous location, marine type, see full specs for complete list of certifications
Features
Industry-leading accuracy and reliability for best performance in critical control and safety applications.
Transmitter-sensor matching improves measurement accuracy up to 75%.
5-year long-term stability extends calibration intervals to reduce trips to the field.
Rosemount X-well Technology measures temperature without a process penetration for reduced design, installation and maintenance costs.
Ordering Information
Model 3144P Temperature transmitter
Housing style D2 Field mount housing, dual-compartment housing
Material: Aluminum
Conduit entry size: M20 1,5 (CM20)
Transmitter output A 4—20 mA with digital signal based on HART Protocol
Measurement configuration 1 Single-sensor input
Product Certificates NA No Approval
Mounting bracket B5 “L” mounting bracket for 2-in. pipe or panel mounting - All SST
Display M5 LCD display
Calibration certification Q4 Calibration certificate (3-point calibration)
Model: 3144P Temperature Transmitter
Manufacturer: Rosemount-Emerson
Condition: New Original in Factory Packing
Factory Warranty: Two Years
Specifications
Input: Dual and single sensor capability with universal sensor inputs (RTD, T/C, mV, ohms)
Output Signal: 4-20 mA /HART® protocol, FOUNDATION™ Fieldbus protocol
Housing: Dual-compartment field mount
Display/Interface: Large LCD display with percent range graph and buttons/switches
Diagnostics: Basic diagnostics, Hot Backup™ capability, sensor drift alert, thermocouple degradation, min/max tracking
Calibration Options: Transmitter-sensor matching (Callendar-Van Dusen constants), custom trim
Certifications/Approvals: SIL 2/3 certified to IEC 61508 by an independent 3rd party, hazardous location, marine type, see full specs for complete list of certifications
Features
Industry-leading accuracy and reliability for best performance in critical control and safety applications.
Transmitter-sensor matching improves measurement accuracy up to 75%.
5-year long-term stability extends calibration intervals to reduce trips to the field.
Rosemount X-well Technology measures temperature without a process penetration for reduced design, installation and maintenance costs.
Ordering Information
Model 3144P Temperature transmitter
Housing style D2 Field mount housing, dual-compartment housing
Material: Aluminum
Conduit entry size: M20 1,5 (CM20)
Transmitter output A 4—20 mA with digital signal based on HART Protocol
Measurement configuration 1 Single-sensor input
Product Certificates NA No Approval
Mounting bracket B5 “L” mounting bracket for 2-in. pipe or panel mounting - All SST
Display M5 LCD display
Calibration certification Q4 Calibration certificate (3-point calibration)