Product Description
Part Number: EJA530E-JBS7N-019DN/ KU22/D3/T06/M15/HAC
Model: EJA530E In-Line Mount Gauge Pressure Transmitter
Brand: Yokogawa
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months
Overview
The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family. Released in 2012, it combines the ruggedness and success of the work-horse EJA-E series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa.
EJA530E's standard features include:
Specifications
Model and Suffix Codes
Model EJA530E Gauge pressure transmitter
Output signal -J 4 to 20 mA DC Output with digital communication (HART 5/HART 7 protocol)(1)
Measurement span (capsule) B 0.1 to 2 MPa (14.5 to 290 psi)
Wetted parts material(2) S Process connector: 316L SST#
Diaphragm: Hastelloy C-276(3)#
Others: 316L SST#
Process connection 7 1/2 NPT male
N Always N
-0 Always 0
Amplifier housing 1 Cast aluminum alloy
Electrical connection 9 M20 female, two electrical connections with a blind plug(4)
Integral indicator D Digital indicator(5)
Mounting bracket N None
ATEX /KU22 Combined KF22, KS21 and ATEX Intrinsically safe Ex ic(6)(7)
[ATEX Intrinsically safe Ex ic]
Applicable Standard: EN 60079-0:2012/A11:2013, EN 60079-11:2012
II 3G Ex ic IIC T4 Gc, Amb. Temp.: ?C30 to 60??C (?C22 to 140??F)(8)
Ui=30 V, Ci=27.6 nF, Li=0 ??H
Calibration units(9) /D3 bar calibration (bar unit)
Pressure test/ Leak test certificate(10) /T06 Test Pressure: 2 MPa (290 psi)(11)
Nitrogen(N2) Gas or Water(12)
Retention time: one minute
Material certificate(13) /M15 Process Connector
High accuracy type(14) /HAC High accuracy
The ????? marks indicates the most typical selection for each specification.
The ??#??marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO 15156. Please refer to the latest standards for details. Selected materials also conform to NACE MR0103.
HART 5 or HART 7 is selectable. Specify upon ordering.
Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user??s process fluids.
Hastelloy C-276 or ASTM N10276.
Material of a blind plug is aluminum alloy or 304 SST.
Not applicable for output signal code G.
Applicable for Electrical connection code 2, 4, 7, 9, C and D.
Not applicable for output signal code Q.
Lower limit of ambient temperature is ?C15??C (5??F) when /HE is specified.
The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option codes D1, D3, and D4.
The unit on the certificate is always kPa/MPa regardless of selection of option code D1, D3 and D4.
Applicable for capsule code B.
Pure nitrogen gas or pure water is used for oil-prohibited use (option codes K1 and K2).
Material traceability certification, per EN 10204 3.1 B.
Not applicable for output signal code Q.
Model: EJA530E In-Line Mount Gauge Pressure Transmitter
Brand: Yokogawa
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months
Overview
The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family. Released in 2012, it combines the ruggedness and success of the work-horse EJA-E series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa.
EJA530E's standard features include:
Specifications
Model and Suffix Codes
Model EJA530E Gauge pressure transmitter
Output signal -J 4 to 20 mA DC Output with digital communication (HART 5/HART 7 protocol)(1)
Measurement span (capsule) B 0.1 to 2 MPa (14.5 to 290 psi)
Wetted parts material(2) S Process connector: 316L SST#
Diaphragm: Hastelloy C-276(3)#
Others: 316L SST#
Process connection 7 1/2 NPT male
N Always N
-0 Always 0
Amplifier housing 1 Cast aluminum alloy
Electrical connection 9 M20 female, two electrical connections with a blind plug(4)
Integral indicator D Digital indicator(5)
Mounting bracket N None
ATEX /KU22 Combined KF22, KS21 and ATEX Intrinsically safe Ex ic(6)(7)
[ATEX Intrinsically safe Ex ic]
Applicable Standard: EN 60079-0:2012/A11:2013, EN 60079-11:2012
II 3G Ex ic IIC T4 Gc, Amb. Temp.: ?C30 to 60??C (?C22 to 140??F)(8)
Ui=30 V, Ci=27.6 nF, Li=0 ??H
Calibration units(9) /D3 bar calibration (bar unit)
Pressure test/ Leak test certificate(10) /T06 Test Pressure: 2 MPa (290 psi)(11)
Nitrogen(N2) Gas or Water(12)
Retention time: one minute
Material certificate(13) /M15 Process Connector
High accuracy type(14) /HAC High accuracy
The ????? marks indicates the most typical selection for each specification.
The ??#??marks indicate the construction materials conform to NACE material recommendations per MR0175/ISO 15156. Please refer to the latest standards for details. Selected materials also conform to NACE MR0103.
HART 5 or HART 7 is selectable. Specify upon ordering.
Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user??s process fluids.
Hastelloy C-276 or ASTM N10276.
Material of a blind plug is aluminum alloy or 304 SST.
Not applicable for output signal code G.
Applicable for Electrical connection code 2, 4, 7, 9, C and D.
Not applicable for output signal code Q.
Lower limit of ambient temperature is ?C15??C (5??F) when /HE is specified.
The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option codes D1, D3, and D4.
The unit on the certificate is always kPa/MPa regardless of selection of option code D1, D3 and D4.
Applicable for capsule code B.
Pure nitrogen gas or pure water is used for oil-prohibited use (option codes K1 and K2).
Material traceability certification, per EN 10204 3.1 B.
Not applicable for output signal code Q.