Product Description
Product Number : IMV31-T22CE21F-M2B1C2L1
Model Description
IMV31 Multivariable Transmitter
Electronics Versions and Output Signal
-T Intelligent; Digital HART and 4 to 20 mA dc (Version -T)
Structure Code - Process Covers, Sensor Material, and Sensor Fill Fluid
Covers Sensor Fill Fluid
22 316 ss 316L ss Silicone
Span Limits - Differential Pressure (DP) Measurement
kPa inH2O mbar Available with (a)
C 2.5 and 210 10 and 840 10 and 840 10 and 840
Span Limits - Absolute Pressure (AP) Measurement (Absolute Measured: Gauge Calculated)
MPaa psia bara or kg/cm2 abs Available with (a)
E 0.21 and 10 (n) 30 and 1500 (n) 2.1 and 100 (n) DP Codes B and C only
Process Connector Type (Material Same as Process Cover Material)
2 1/2 NPT
Conduit Connection and Housing Material
1 1/2 NPT Connection, Aluminum Housing
Electrical Safety
F FM approved Division 1 intrinsically safe, explosionproof, dust-ignitionproof, and nonincendive,
Division 2, Classes I, II, and III. ALso zone approved instrinsically safe AEx ia IIC.
Mounting Bracket Set
-M2 Stainless Steel Bracket with Stainless Steel Bolts
Bolting for Process Covers/Connectors (b)
B1 316 ss Bolts and Nuts
Custom Factory Configuration
C2 Full Factory Configuration (Requires completion of Multivariable Configuration Wizard before entering the order) (c)
Digital Indicator with Pushbuttons
L1 Digital Indicator, Pushbuttons, and Window Cover
(a) Refer to Functional Specifications section for allowable combinations of DP and AP Span Limit Codes.
(b) Not available with DIN 19213 Construction options. For stainless steel bolting with DIN 19213, specify -D5, -D6, -D7, or -D8.
(c) IPS recommends the selection of Option -C2 if the application information is known. If Option -C2 is not selected, a standard default
configuration will be provided. The user will then need the Model PCMV to completely configure the transmitter for liquid level applications.
Model Description
IMV31 Multivariable Transmitter
Electronics Versions and Output Signal
-T Intelligent; Digital HART and 4 to 20 mA dc (Version -T)
Structure Code - Process Covers, Sensor Material, and Sensor Fill Fluid
Covers Sensor Fill Fluid
22 316 ss 316L ss Silicone
Span Limits - Differential Pressure (DP) Measurement
kPa inH2O mbar Available with (a)
C 2.5 and 210 10 and 840 10 and 840 10 and 840
Span Limits - Absolute Pressure (AP) Measurement (Absolute Measured: Gauge Calculated)
MPaa psia bara or kg/cm2 abs Available with (a)
E 0.21 and 10 (n) 30 and 1500 (n) 2.1 and 100 (n) DP Codes B and C only
Process Connector Type (Material Same as Process Cover Material)
2 1/2 NPT
Conduit Connection and Housing Material
1 1/2 NPT Connection, Aluminum Housing
Electrical Safety
F FM approved Division 1 intrinsically safe, explosionproof, dust-ignitionproof, and nonincendive,
Division 2, Classes I, II, and III. ALso zone approved instrinsically safe AEx ia IIC.
Mounting Bracket Set
-M2 Stainless Steel Bracket with Stainless Steel Bolts
Bolting for Process Covers/Connectors (b)
B1 316 ss Bolts and Nuts
Custom Factory Configuration
C2 Full Factory Configuration (Requires completion of Multivariable Configuration Wizard before entering the order) (c)
Digital Indicator with Pushbuttons
L1 Digital Indicator, Pushbuttons, and Window Cover
(a) Refer to Functional Specifications section for allowable combinations of DP and AP Span Limit Codes.
(b) Not available with DIN 19213 Construction options. For stainless steel bolting with DIN 19213, specify -D5, -D6, -D7, or -D8.
(c) IPS recommends the selection of Option -C2 if the application information is known. If Option -C2 is not selected, a standard default
configuration will be provided. The user will then need the Model PCMV to completely configure the transmitter for liquid level applications.